1번 이미지
  • 1번 이미지
Ossila Dual Syringe Pump
· 대표판매가
10
· 공  급  원
해외제조사
· 판  매  처
옴니사이언스
· 연  락  처
031-217-7950
· 리 드 타 임
담당자 문의
· 옵 션 보 기
옵션선택   관심상품
· 관련컨텐츠

Ossila 제품은 환율 등에 따라 단가가 달라지는 제품이므로 이메일로 문의 주시면 감사하겠습니다.

(옴니사이언스는 Ossila의 한국 공식 distributor입니다.)

이메일 문의 : omniscience001@gmail.com


 

With two laboratory syringe pumps in one, each pump can be controlled independently and operated in either infusion or withdrawal mode. The Ossila Dual Syringe Pump provides flexibility and makes it simple to carry out complex experiments.

An affordable, versatile piece of processing equipment that offers high quality. Our dual syringe pump includes precision stepper motors and integrated software with an intuitive interface. Plus, this system also features a universal syringe clamp and channel, independent safety switches, and stall detection.

Two-Year Warranty

Two-Year Warranty

Covered by the Ossila Warranty

Dual Syringe Pump Precision Timing

Precision Timing

Effortless automatic dispensing

Lightweight Dual Syringe Pump

Lightweight

Lightweight and durable design

Dual Syringe Pump Precision Motion

Precision Motion

Quality motors ideal for sensitive experiments



Specifications


 
Syringe Channels 2
Channel Dependency Independent channel control
Operation Modes Infusion and withdrawal
Minimum Syringe Size 0.5 μl
Maximum Syringe Size 60 ml
Safety Features Limit switches, Crashing sensing
Power 24 V DC, 2.0 A
Power Supply Input Voltage Range 100 – 230 V, 50/60 Hz, 50 VA
Operating Temperature/Humidity 5 °C to 40 °C (41 °F to 104 °F); Up to 80% RH at 31 °C (87.8 °F)
Overall Dimensions (W x H x D) 330 mm x 140 mm x 260 mm (13.0" x 5.5" x 10.2")
 
 

Motor

Motor Type NEMA 17 Stepper Motor
Step Angle 1.8°
Steps per Full Revolution 200
Screw Pitch 1 mm
Travel per Step 5 µm
Maximum Linear Force 500 N

Driver

Micro Stepping 1/64
Micro Steps per Revolution 12,800
Minimum Step Rate N/A
Maximum Step Rate 1000 steps.s-1
Minimum Speed 12 µm.s-1
Maximum Speed* 5 µm.s-1
Rate Accuracy** ±3%

* The maximum speed can exceed the value stated above dependent upon solution viscosity, syringe diameter, tube/needle diameter, and tube/needle length.

** The Ossila Dual Syringe Pump has a stepping accuracy of 0.16%, which gives a rate accuracy of 19 nm.s-1. In practice, the accuracy of the flow rate from a syringe pump depends on the accuracy of the driver and the syringe diameter. Different syringes have different manufacturing tolerances. The  diameter of plastic disposable syringes can vary by up to 3%, resulting in an error in dispense rate of up to 6%. Glass and stainless steel syringes have a higher tolerance, with a maximum of 0.5% variation in the internal diameter and volume error of up to 1%.

Software

Number of Programs 10
Steps per Program 100
Syringe Size Settings 5 pre-sets, 1 customisable diameter
Force Tuning 5% to 100% (5% increments)
Memory Non-volatile memory

Syringe Compatibility

Syringe Types

Norm-Ject syringes

Henke Sass Wolf (HSW)

Terumo Plastic

Hamilton Gastight

Hamilton Microliter

Air-Tite Syringes

BD Plastic

BD Glass

SGE Syringes

and more...

Maximum and Minimum Flow Rate

The maximum and minimum flow rate of the syringe pump is determined by the stepping rate of the motor and the diameter of the syringe. Maximum and minimum flow rates for some common syringe sizes are shown below. By choosing the correct syringe diameter, it is possible to achieve a range of dispense rates spanning 8 orders of magnitude.

Syringe Volume Syringe Diameter Minimum Flow Rate Maximum Flow Rate
0.5 µl 0.103 mm 0.1 nl.s-1 (0.14 µl.hr-1) 41 nl.s-1 (0.15 ml.hr-1)
10 µl 0.46 mm 1.98 nl.s-1 (6.8 µl.hr-1) 0.83 µl.s-1 (3 ml.hr-1)
100 µl 1.46 mm 19 nl.s-1 (68 µl.hr-1) 8.3 µl.s-1 (29.8 ml.hr-1)
1 ml 4.61 mm 0.2 µl.s-1 (0.72 ml.hr-1) 83 µl.s-1 (298 ml.hr-1)
5 ml 10.3 mm 1 µl.s-1 (3.6 ml.hr-1) 0.42 ml.s-1 (1.5 l.hr-1)
50 ml 32.6 mm 10 µl.s-1 (36 ml.hr-1) 4.17 ml.s-1 (15 l.hr-1)

Product Certification and Standards

CE

Machinery Directive 2006/42/EC

EMC Directive 2014/30/EU

RoHS Directive 2011/65/EU
UKCA

Supply of Machinery (Safety) Regulations

Electromagnetic Compatibility Regulations

Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations
Harmonised Standards BS EN ISO 12100:2010 Safety of Machinery - General Principles for Design - Risk Assessment and Risk Reduction
wait..

배송/반품/교환 안내

공급사 정보
옴니사이언스 고객센터
    Tel. 031-217-7950  /  Fax. 031-215-7950
출고시스템
    오후 1시까지의 결제완료건 당일 출고 (단 재고 보유 상품일 경우에 해당)
상담가능시간
    평일 오전 9시~12시 / 오후 1시~6시, 토요일, 일요일, 공휴일 휴무
배송 안내
택배발송 : 출고시 가장 빠르게 배송 가능한 업체
화물발송 : 택배로 운송될 수 없는 상품 (예: 장비류, Cart류, 규격Size이상의 크기, 초과중량의 상품)
배송비 
1. 택배발송
(1)일반고객, 소비자
  - 주문금액 100,000원 미만 : 운임비 고객 부담. 착불 또는 주문시 결제가능
  - 주문금액 100,000원 이상 : 운임비 판매자 부담 (단, 택배배송 불가능 상품은 고객부담)
(2)납품업체, 딜러
  - 주문금액 100,000원 미만 : 운임비 고객 부담. 착불 또는 주문시 결제가능
  - 주문금액 100,000원 이상 : 운임비 판매자 부담 (단, 택배배송 불가능 상품은 고객부담)
2. 화물발송
 택배발송이 불가한 상품, 장비류(Oven, Autoclave, Mill, Cart류 등), Glass Tube, 등의 운임비 별도로 명시된 상품 : 운임비 고객부담
• 제주도 및 도서 산간지역의 경우 추가 운임비가 발생할 수 있습니다
• 재고 보유 상품과 미보유 상품을 동시에 주문 하시는 경우, 재고 보유 상품의 금액(출고 금액) 기준으로 운임비가 부과됩니다
반품/교환
1. 교환 및 반품이 가능한 경우
 (1)상품배송 완료 후, 14일 이내에 상품에 하자가 없는 경우
 (2)포장상태에 이상이 없고, 재판매가 가능한 경우  (단, 왕복 택배비는 고객님께서 부담하셔야 합니다)
2. 교환 및 반품이 불가능한 경우
 (1)반품 요청 기간이 지난 경우
 (2)주문 당시 재고가 없어, 해외 발주 상품의 경우
 (3)포장을 개봉하였거나 포장 및 제품이 훼손되어 상품가치가 현저히 상실되고 재판매가 불가능한 경우
 (4)구매자의 책임 있는 사유로 상품 등이 멸실 또는 훼손된 경우
 (5)고객의 주문에 의해 제작되는 주문제작의 경우
 (6)반품으로 배송되는 과정 중 파손된 경우 (택배사의 주의 혹은 부실포장으로 인한 파손이므로 반품불가)
제품 고장 및 A/S
구매하신 장비의 고장이나 불량이 의심 될 경우 고객센터 (031-217-7950)에 사전 문의 후 A/S가 가능합니다
1.신청방법
 (1) 상담센터  (031-217-7950)
2. A/S 과정
 (1) 절차에 따라 택배발송 또는 화물 발송.
 (2) 수리비 발생시 고객님께 통보, 입금 확인 후 제품 발송
3. 무상 A/S
 (1) 장비구매시, 구매인증 하신 후 1년
 (2) 무상 A/S 불가능할 경우 :
    ① 장비를 임의로 개조하여 사용하였을 경우
    ② 주문제작으로 가공된 초자 가공품류(꼭! 상담을 먼저 해주세요.)
세금계산서/현금영수증
• 세금계산서는 공급사에서 발행하며, 현금영수증 증빙은 올포랩의 오픈마켓에서 발급됨을 참고하시기 바랍니다
• 올포랩은 오픈마켓의 판매대행 업체로서 고객님의 입금/신용카드 결제는 올포랩 오픈마켓에서 이루어지고 있습니다.
  거래에 관한 자세한 안내는 구매하신 올포랩 고객센터로 문의해 주시기 바랍니다. (올포랩 : 1661-1179)

닫기
최근 본 상품